Introducing the Cypher™ AFM |
|
Break the Nanocode with the Next Generation of AFM You’ve been expecting something genuinely new from the AFM/SPM industry, but for many years you’ve only seen tweaks to old technology. Now Asylum Research introduces the Cypher™ AFM, the first totally new small sample AFM/SPM in over a decade. More capability, more control, more functionality, more modularity, and more resolution – all with striking ease of use.
|
||
|
|
||
Closed loop atomic resolution using sensors in all three axes ensures the highest resolution and most accurate images possible today. With the Cypher AFM, you no longer have to choose between the accuracy and control of closed loop and the low noise of open loop. Asylum’s third generation NanoPositioning System (NPS™) sensors are the quietest in the world today. With positioning accuracies better than 60 picometers in X, Y and Z, you not only achieve atomic resolution in closed loop, you also get the most accurate measurements, positioning and nanomanipulation possible. |
Closed loop STM showing graphite atoms, 6nm scan. |
|
|
|
||
| SpotOn™ automated laser alignment provides extraordinary ease of use. With Cypher’s fully motorized laser and photodiode positioning, a mouse click aligns the laser spot on your cantilever and centers your photodetector. |
SpotOn Alignment Just click on the desired spot location and the motorized stages automatically align the laser spot. The photodiode signals are also automatically centered. |
|
|
|
||
Laser spot sizes as small as 3µm enable high-speed AC imaging with small cantilevers. Cypher provides the industry’s smallest spot size, allowing you to use cantilevers smaller than 10µm for fast imaging and sub-picoNewton force measurements.
|
Small Cantilevers provide much higher resonant frequencies than conventional cantilevers without an increase in stiffness. |
|
|
|
||
Designed from the Ground Up Cypher’s proprietary system-level mechanical design is inherently immune to normal environmental vibration, eliminating the need for additional isolation add-ons for most labs. The integrated system enclosure includes thermal control and provides additional acoustic isolation for noisy environments. This system-level design creates images of atomically flat samples that are free of periodic noise. Cypher also features unimpeded 180 degree optical/mechanical access to your samples and a small 40x42cm footprint that conserves lab space. |
![]() |
|
|
|
||
| Interchangeable modules broaden your options for applications and scanning modes. MultiLux™ source modules are available with laser diodes and low-coherence SLDs in a variety of spot sizes to provide optimal signal-to-noise over a wide range of cantilever lengths. Module exchange takes only a minute. |
MultiLux Optics The focused spot size can easily be changed to fit the size of the cantilever being used. Here, two different spot sizes are shown on two different cantilevers. The small spot has dimensions of 3x9µm. |
|
|
|
||
| High resolution top-view optics with Köhler illumination provide crystal clear viewing of your sample and tip. Cypher’s custom optics with 20X objective are limited only by physical diffraction. You’ll see sub-micron resolution over a 690x920µm field of view with digital zoom and pan. |
Diffraction-limited Optics 3.1 megapixel top view image shows AFM calibration grating (20µm pitch) with inset of 8X digital zoom. |
|
|
|
||
| Cypher’s integrated enclosure provides thermal control and acoustic isolation to optimize imaging and measurement stability. Achieve >10X improvement in thermal drift compared to older, less advanced SPMs. | ![]() |
|
|
|
||
The World’s Highest Resolution Closed Loop AFM With the Cypher AFM, you can do things that are simply not possible with other AFMs. Here are some examples of how the Cypher AFM can help you decode the nanoworld. |
||
Closed loop image of domains of surfactant hemi-micelles surrounding a defect on graphite, 200nm scan. |
Closed loop Dual AC Mode image of collagen. Second mode amplitude is overlaid on topography, 300nm scan. |
|
Closed loop image of surface potential overlaid on topography of a biased electrode. Voltage drop ~1V, 20µm scan. |
Closed loop image of Lambda digest DNA imaged in buffer, 530nm scan. |
|
Closed loop image of extracellular face of bacteriorhodopsin in buffer, 50nm scan.
|
Closed loop image of cleavage defects on graphite surface, 1.7µm scan.
|
|
|
|
||
Scanning Modes Standard
Optional
|
||
|
|
||
Unbreakable Nanocode? You need the new Cypher AFM to make tomorrow’s discoveries and to keep your facility first in science. With capabilities far beyond those of older SPMs – and modularity and expandability for the future – the Cypher AFM can help you be a leader in decoding the nanoworld. The Asylum Research team will support you every step of the way. Asylum’s legendary product and applications support ensures you get up and running quickly and achieve optimum results. Asylum is the clear leader in customer satisfaction. If you’re not already an Asylum user, just ask one (or ask us for a reference).
|
||
|
|
||
Seek Asylum for the Most Advanced AFM/SPM Technology and Tools Choose the Cypher AFM for:
Choose MFP-3D™ AFM for:
|
||
|
|
||
Specifications Head/Optical Lever
*Noise measurements are quoted as average deviation (Adev) in a 0.1Hz to 1kHz bandwidth. Scanner A variety of scanner modules are available depending on application. All scanner modules include XYZ actuation as well as a motorized cantilever engage stage. The standard scanner module specs are listed below:
*Noise measurements are quoted as average deviation (Adev) in a 0.1Hz to 1kHz bandwidth. View Module A variety of view modules providing top-down optical view of the sample/cantilever are possible depending on the application. The standard view module specifications are listed below:
Electronics
Data Acquisition Data size is limited only by the memory on the PC (10 million point and 8k x 8k images are possible). Additionally, a continuously running circular fast capture buffer allows high speed data to be sent to the computer at any time. Computer Minimum: Dell Precision T3400 mini-tower, 2.40GHz Quad Core, 2GB RAM, 160GB SATA RAID hard drive, 16x DVD writer, dual 20” LCD panels (30” optional), 525W supply, Windows XP Pro. Software The software is based in IGOR Pro by WaveMetrics, a powerful scientific data acquisition and analysis environment. The software is user programmable. Features include:
ARgyle™: OpenGL® 3D rendering technology for advanced image display.
Instrument Isolation
|
||
|